ACT offers a complete line of Optical Splitters, which feature low insertion loss, high isolation and excellent wavelength stability. The optical splitters come as different form factor packages, 1RU 19” rack-mount chassis, standard LGX modules or flat box assemblies. The Planar lightwave circuit (PLC) splitter is a type of optical power management device that is fabricated using silica optical waveguide technology. It features small size, high reliability, wide operating wavelength range and good channel-to-channel uniformity, and is widely used in PON networks to realize optical signal power splitting. ACT developed the complete series of 1xN and 2xN splitter products that are tailored for specific applications suc as HFC, FTTx (P2P, P2MP), RFOG (Radio Frequency over Glass) applications, permitting DOCSIS and HFC to operate over a EPON/GPON compliant Passive Optical Network (PON) as commonly deployed for Fibre to the Home (FTTH) developments solution in high density FTTX networks to bring the video services to business and home premises.
§ Full Line of Optical Passives and Accessories
§ Cost Effective Solution
§ High Port Isolation
§ Low Insertion Loss
§ Flexibility for Customization
§ Wide Operating Wavelength: From 1260nm to 1650nm
§ Wide Operating Temperature: From -40°C to 85°C
§ High Reliability and Stability
ACT Optical Passives Optical Splitters (AOS)
Optical Specifications | ||
Operating Wavelength | 1260 nm to 1650 nm | |
Configuration | 1x2 | |
Insertion Loss | Varies. See below chart | |
Uniformity | ≤0.6 dB | |
Directivity | ≥50 dB | |
Polarization Dependent Loss | ≤0.1 dB | |
Return Loss | ≥55 dB | |
Connectors | SC/APC, SC/PC, LC/APC, LC/PC | |
Fiber Types | 900 µm, 2 mm, or 3 mm | |
General Specifications | ||
Operating Temperature | -20 °C to +70 °C | |
Storage Temperature | -40 °C to +85 °C | |
Operating Humidity | 5 % to 95 % RH (non-condensing) | |
Dimensions (W × D × H) | LGX, Splice Tube or Flat Box (ABS): 100 mm × 80 mm × 10.5 mm | |
Weight | Weight varies depending on model. |
Split Ratio Typical Insertion Loss (dB)
50/50 3.6/3.6
55/45 3.1/4.3
60/40 2.8/4.8
65/35 2.3/5.3
70/30 2.1/6.1
75/25 1.6/7.2
80/20 1.3/8.0
85/15 1.2/9.6
90/10 0.9/11.3
95/05 0.6/15
Note: Contact ACT for different packaging options. Losses excluding connector loss (a pair of connector loss max: 0.2 dB)
ACT Optical Passives Optical Splitters (AOS)
Optical Specifications | ||
Operating Wavelength | 1260 nm to 1650 nm | |
Configuration | 1x3 | |
Insertion Loss | Varies. See below chart | |
Uniformity | ≤0.6 dB | |
Directivity | ≥50 dB | |
Polarization Dependent Loss | ≤0.2 dB | |
Return Loss | ≥55 dB | |
Connectors | SC/APC, SC/PC, LC/APC, LC/PC | |
Fiber Types | 900 µm, 2 mm, or 3 mm | |
General Specifications | ||
Operating Temperature | -20 °C to +70 °C | |
Storage Temperature | -40 °C to +85 °C | |
Operating Humidity | 5 % to 95 % RH (non-condensing) | |
Dimensions (W × D × H) | LGX, Splice Tube, or Flat Box (ABS): 100 mm × 80 mm × 10.5 mm (≤8 output ports), 140 mm × 115 mm × 18 mm (>8 output ports) | |
Weight | Weight varies depending on model |
Split Ratio Typical Insertion Loss (dB)
80/10/10 1.3/11.4/11.4
70/15/15 2/9.7/9.7
60/20/20 2.8/8/8
50/25/25 3.7/7.1/7.1
40/30/30 4.3/5.6/5.6
33/33/33 5.2/5.2/5.2
30/35/35 5.6/4.9/4.9
Note: Contact ACT for different packaging options. Losses excluding connector loss (a pair of connector loss max: 0.2 dB)
ACT Optical Passives Optical Splitters (AOS)
Optical Specifications | |
Operating Wavelength | 1260 nm to 1650 nm |
Configuration | 1x4, 1x5, 1x6 |
Insertion Loss | Varies. See below chart |
Uniformity | ≤0.6 (1x4) ≤0.8 (1x5, 1x6) ≤1.8 (1x8) |
Directivity | ≥50 dB |
Polarization Dependent Loss | ≤0.3 dB |
Return Loss | ≥ 55 dB |
Connectors | SC/APC, SC/PC, LC/APC, LC/PC |
Fiber Types | 900 µm, 2 mm, or 3 mm |
General Specifications | |
Operating Temperature | -20 °C to +70 °C |
Storage Temperature | -40 °C to +85 °C |
Operating Humidity | 5 % to 95 % RH (non-condensing) |
Dimensions (W × D × H) | LGX, Splice Tube or Flat Box (ABS): 100 mm × 80 mm × 10.5 mm |
Weight | Weight varies depending on model. |
Split ratio Typical Insertion Loss (dB)
25/25/25/25 6.8
1x5 Balanced 7.8
1x6 Balanced 8.7
1x8 Balanced 10.2
Note: Contact ACT for different packaging options. Losses excluding connector Loss (a pair of connector loss max: 0.2 dB)
ACT Optical Passives Optical Splitters (AOS)
Optical Specifications | |
Operating Wavelength | 1260 nm to 1650 nm |
Configuration | 1x16, 1x32, 1x64 |
Insertion Loss | Varies. See below chart |
Uniformity | ≤1.2 dB (1x16); ≤1.5 dB (1x32); ≤2.5 dB (1x64) |
Directivity | ≥55 dB |
Polarization Dependent Loss | ≤0.4 dB |
Return Loss | ≥ 55 dB (Bare Fiber or APC) |
Connectors | SC/APC, SC/PC, LC/APC, LC/PC |
Fiber Types | 900 µm, 2 mm, or 3 mm |
General Specifications | |
Operating Temperature | -20 °C to +70 °C |
Storage Temperature | -40 °C to +85 °C |
Operating Humidity | 5 % to 95 % RH (non-condensing) |
Dimensions (W × D × H) | LGX, Flat Box, or splice fiber tray |
Weight | Weight varies depending on model. |
Split ratio Typical Insertion Loss (dB) Max. Insertion Loss (dB)
1x16 Balanced 13 13.5
1x32 Balanced 16 16.9
1x64 Balanced 19.5 21.0
Note: Contact ACT for different packaging options. Losses excluding connector Loss (a pair of connector loss max: 0.2 dB)
ACT Optical Passives Optical Splitters (AOS)
Item | Description | ||||||
Operating Wavelength | 1260 nm to 1650 nm | ||||||
Configuration | 2x2, 2x4, 2x8, 2x16, 2x32, 2x64 | ||||||
Type | 2x2 | 2x4 | 2x8 | 2x16 | 2x32 | 2x64 | |
Insertion Loss (dB) | Typ. | 4.0 | 7.0 | 10.5 | 13.5 | 16.5 | 20.5 |
Max. | 4.1 | 7.4 | 10.8 | 14.3 | 17.3 | 20.7 | |
Uniformity (dB) | Typ. | 0.6 | 0.8 | 1.0 | 1.5 | 2.0 | 2.0 |
Max. | 0.8 | 0.8 | 1.5 | 2.0 | 2.5 | 2.5 | |
PDL (dB) | Typ. | 0.1 | 0.1 | 0.1 | 0.2 | 0.2 | 0.2 |
Max. | 0.2 | 0.2 | 0.3 | 0.4 | 0.4 | 0.4 | |
Wavelength Dependent Loss (dB) | Typ. | 0.10 | 0.10 | 0.10 | 0.30 | 0.40 | 0.70 |
Max. | 0.20 | 0.30 | 0.40 | 0.60 | 0.80 | 1.00 | |
Temperature Dependent Loss | Typ. | 0.30 | 0.30 | 0.30 | 0.40 | 0.40 | 0.40 |
Max. | 0.50 | 0.50 | 0.50 | 0.50 | 0.50 | 0.50 | |
PLC Splitter Bare Fiber (mm) | 4x4x55 | 4x4x55 | 4x4x55 | 4x7x60 | 4x7x60 | 4x7x60 | |
PLC Splitter Blockless (mm) | 4x4x55 | 4x12x60 | 4x12x60 | 4x12x80 | 6x20x80 | 6x20x80 | |
PLC Splitter Module (mm) | 100x80x10 | 100x80x10 | 100x80x10 | 120x80x18 | 120x80x18 | 141x115x18 | |
Directivity | 55 dB min. | ||||||
Return Loss | 55 dB (50) min. | ||||||
Operating Temperature | -40 °C +85 °C | ||||||
Storage Temperature | -40 °C to +85 °C | ||||||
Fiber Length | 1 m or customized | ||||||
Fiber Type | G652D, G657A or other | ||||||
Connector Type | Customized | ||||||
PLC-splitter-rack-mountable | 19” 1U 2U rack-mounted box, LGX box, ODF box |
Note: Contact ACT for different packaging options. Losses excluding connector loss (a pair of connector loss max: 0.2 dB)
Optical Shelf Specifications | ||||
Material | 1.5 mm thick cold-rolled sheet | |||
Capacity | Host up to 3 LGX modules (1RU), Host up to 14 Metal LGX modules (3RU), Host up to 16 Plastic LGX modules (3RU), Host up to 12 LGX modules (4RU) | |||
Dimensions (W × H × D) | With mounting bracket 483 mm × 44 mm × 320 mm (1RU) With mounting bracket 483 mm × 133 mm × 305 mm (3RU) | |||
With mounting bracket 483 mm × 177 mm × 305 mm (4RU) | ||||
Model Number | AOP-LGX-CH-1RU, AOP-LGX-CH-3RU, AOP-LGX-CHP-3RU, AOP-LGX-CH-4RU | |||
Optical Distribution Frame Specifications | ||||
Material | 1.5 mm thick cold-rolled sheet, 1 to 4RU | |||
Insertion Loss | ≤0.5 dB | |||
Optical Connector | AS: SC/APC; US: SC/UPC; AF: FC/APC or UF: FC/UPC | |||
Return Loss | PC ≥ 40 dB, UPC ≥ 50 dB, APC ≥ 60 dB | |||
Model Number | AOP-ODF-DXX-YY (XX: 36, 48, 72, 96 Fiber, YY: Optical Connector) | |||
General Specifications | ||||
Operating Temperature | -40 °C to +85 °C | |||
Storage Temperature | -40 °C to +85 °C | |||
Operating Humidity | 5 % to 95 % RH (non-condensing) | |||
Weight | Varies by model type | |||
Note: Contact ACT for different packaging options. 8° angle polished
ACT Optical Passive Shelf 1RU (3 LGX slots) Mechanical Design Diagram:
Top View without Cover
Front View with Dimensions
Top and Side View
Optical Passives for HFC, FTTx, and RFoG Solutions
Optical Passives for HFC & FTTH PON Solutions
Optical Passive DWDM
Optical Passive CWDM
Optical Passive (1x2 UB Splitter)
Optical Passive (Fast Connector)
ODF Termination Box
Fiber Optic Splice Closure w/ Splitter
Get in touch with our experts