Ascent MTP/MPO trunk multi-fiber cable assemblies facilitate rapid deployment of high density backbone cabling in data centers and other high fiber environments, reducing network installation or reconfiguration time and cost.
· MTP® connector, MPO Plus premium connector
· Multimode fiber, SMF Ultra optical fiber
· OS2, OM3, OM4 available
· 0.35 dB elite low loss connector, 0.5 dB standard loss connector
· Factory terminated and tested
· Supports 40G ,100G,200G,400G and 800G network applications
· Pulling eyes are provided as an option to protect the fiber ends during installation
· Cable Jacket material: LSZH, OFNR, OFNP available
Fiber Count  | 8‑144 Fibers  | 
Fiber Mode  | Single‑mode: OS2 9/125 µm Multi‑mode: OM4 50/125 µm, OM3 50/125µm  | 
Fiber Brand  | Corning ClearCurve® multimode fiber and SMF‑28® Ultra optical fiber  | 
Connector Type  | MTP Female, Male; MPO Female, Male  | 
Connector Brand  | US Conec MTP®, Senko MPO  | 
Polarity  | Type A, Type B, Type C  | 
Cable Jacket Ratings  | Plenum (OFNP) Low Smoke Zero Halogen (LSZH) Riser (PVC)  | 
Cable Type  | Bunch  | 
Color Codes  | MTP  | MPO  | 
Cable Jackets  | OS2: Yellow OM4: Magenta OM3: Aqua  | OS2: Yellow OM4: Magenta OM3: Aqua  | 
Connectors  | OS2: Green OM4/OM3: Aqua  | OS2: Green OM4/OM3: Aqua  | 
Boots  | 8 Fibers: Grey 12 Fibers: Black 24 Fibers: Red  | 8/12/24 Fibers: Black  | 
Physical Properties  | |
Cable Diameter*  | 3.0 mm  | 
Breakout Length  | 0.5/0.3 m  | 
Minimum Bend Radius  | Single‑mode: 10.0 mm Multi‑mode: 7.5 mm  | 
Operating Temperature  | ‑10 °C to +70 °C  | 
Storage Temperature  | ‑40 °C to +85 °C  | 
* Please note that the cable diameter of standard single MTP/MPO cable is 3.0 mm, and for cables with different bundles, the diameter is different, as shown below:
Bundle Count  | MTP/MPO‑12  | MTP/MPO‑24  | Trunk Diameter  | 
2 Bundles*  | 24 Fibers  | 48 Fibers  | 6.0 mm  | 
3 Bundles  | 36 Fibers  | 72 Fibers  | 8.0 mm  | 
4 Bundles  | 48 Fibers  | 96 Fibers  | 8.0 mm  | 
6 Bundles  | 72 Fibers  | 144 Fibers  | 8.0 mm  | 
8 Bundles  | 96 Fibers  | /  | 10.0 mm  | 
12 Bundles  | 144 Fibers  | /  | 10.0 mm  | 
* “Bundle” means a combination of several fibers. For example, for MTP/MPO‑12 cables, 2 bundles means 24 fibers (2x12); for MTP/MPO‑24 cables, 2 bundles means 48 fibers (2x24).
Optical Properties  | |
Attenuation  | Single Mode: ≤0.32 dB/km at 1310 nm, ≤0.18 dB/km at 1550 nm Multi‑mode: ≤2.3 at 850 nm, ≤0.6 at 1300 nm  | 
Insertion Loss  | Single‑mode: ≤0.35 dB Multi‑mode: ≤0.35 dB  | 
Return Loss  | Single‑mode: UPC polish: ≥50 dB, APC polish: ≥60 dB Multi‑mode: ≥25 dB  | 
Wavelength  | Single‑mode: 1310/1550 nm Multi‑mode: 850/1300 nm  | 
Transmission Distance  | OM4: 150 m at 40/100G, 400 m at 10G OM3: 100 m at 40/100G, 300 m at 10G  |