Ascent QSFP+ LR4 is designed to operate over single-mode fiber system using 4X10 CWDM channel in 1310 band and links up to 10km. The module converts 4 inputs channel of 10Gb/s electrical data to 4 CWDM optical signals, and multiplexes them into a single channel for 40Gb/s optical transmission. Reversely, on the receiver side, the module optically de-multiplexes a 40Gb/s input into 4 CWDM channels signals, and converts them to 4 channel output electrical data. The central wavelengths of the 4 CWDM channels are 1271, 1291, 1311 and 1331 nm. It contains a duplex LC connector for the optical interface and a 38-pin connector for the electrical interface. Single-mode fiber (SMF) is applied in this module. This product converts the 4-channel 10Gb/s electrical input data into CWDM optical signals (light), by a 4-wavelength Distributed Feedback Laser (DFB) array. The 4 wavelengths are multiplexed into a single 40Gb/s data, propagating out of the transmitter module via the SMF. The receiver module accepts the 40Gb/s optical signals input, and de-multiplexes it into 4 CWDM 10Gb/s channels. Each wavelength light is collected by a discrete photo diode, and then outputted as electric data after amplified by a TIA. The product is designed with form factor, optical/electrical connection and digital diagnostic interface according to the QSFP+ Multi-Source Agreement (MSA) and compliant to 40G QSFP+ LR4 of IEEE 802.3ba.
· Supports 41.2 Gb/s aggregate bitrates
· Uncooled 4x10Gb/s transmitter
· Maximum link length of 10km on Single Mode Fiber (SMF)
· Hot-pluggable QSFP+ footprint
· Duplex LC receptacles
· Power consumption<3.5W
· RoHS-6 compliant and lead-free
· Single 3.3V power supply
· Support Digital Diagnostic Monitor interface
· Case operating temperature
Commercial: 0°C to +70°C
Absolute Maximum Ratings
Parameter | Symbol | Min. | Typ. | Max. | Unit | Note |
Storage Temperature | TS | -40 | 85 | °C | ||
Storage Ambient Relative Humidity | HA | 0 | 85 | % | ||
Maximum Supply Voltage | VCC1, VCCTX, VCCRX | -0.5 | 3.6 | V | ||
Signal Input Voltage | -0.3 | Vcc+0.3 | V | |||
Receiver Damage Threshold | +3.4 | dBm | ||||
Lead Soldering Temperature/Time | TSOLD | 260/10 | °C/sec | 1 | ||
Lead Soldering Temperature/Time | TSOLD | 360/10 | °C/sec | 2 |
Parameter | Value | Unit | Note |
Module Form Factor | QSFP+ | ||
Number of Lanes | 4 Tx and 4 Rx | ||
Maximum Aggregate Data Rate | 41.2 | ||
Maximum Data Rate per Lane | 10.3125 | Higher bit rates may be supported. Please contact Ascent | |
Protocols Supported | Typical applications include 40G Ethernet | ||
Management Interface | Serial,I2c-based,400kHz maximum frequency | As defined by the QSFP+ MSA |
Parameter | Symbol | Min. | Typ. | Max. | Unit | Note |
Storage Temperature | BR | 10313 | Mb/s | 1 | ||
Storage Ambient Relative Humidity | BER | 10-12 | 2 | |||
Signal Input Voltage | d | 10 | km | 3 |
Notes:
1. Compliant with 40GBASE-LR4 and XLPPI per IEEE 802.3ba. Compatible with 1/10 Gigabit Ethernet and 1/2/4/8/10G Fibre Channel.
2. Tested with a PRBS 231-1 test pattern.
3. Per 40GBASE-LR4, IEEE 802.3ba.
Optical Parameters
Parameter | Symbol | Min. | Typ. | Max. | Unit |
Transmitter | |||||
Total Average Launch Power | POUT | 8.3 | dBm | ||
Average Output Power per lane | POUT | -7 | 2.3 | dBm | |
Transmit OMA per Lane | TxOMA | -4.0 | 3.5 | dBm | |
Extinction Ratio | ER | 3.5 | dB | ||
Center Wavelength | λC | 1264.5 | 1271 | 1277.5 | nm |
1284.5 | 1291 | 1297.5 | nm | ||
1304.5 | 1311 | 1317.5 | nm | ||
1324.5 | 1331 | 1337.5 | nm | ||
Side-mode Suppression Ratio | SMSR | 30 | - | - | dB |
Transmitter and Dispersion Penalty | TDP | 3.5 | dB | ||
Transmitter OFF Output Power | POff | -30 | dBm | ||
Transmitter Eye Mask Definition {X1, X2, X3, Y1, Y2, Y3} | {0.25, 0.4, 0.45, 0.25, 0.28, 0.4} | ||||
Receiver | |||||
Input Optical Wavelength | λIN | 1264.5 | 1271 | 1277.5 | nm |
1284.5 | 1291 | 1297.5 | nm | ||
1304.5 | 1311 | 1317.5 | nm | ||
1324.5 | 1331 | 1337.5 | nm | ||
Rx Sensitivity per lane | RSENS1 | -11.5 | dBm | ||
Rx Sensitivity(OMA) | RSENS2 | -9.6 | dBm | ||
InputSaturation Power (Overload) | PSAT | +3.4 | dBm | ||
Receiver Reflectance | Rfl | -12 | dBm | ||
Loss of Signal Assert | PA | -30 | dBm | ||
Loss of Signal De-assert | PD | -12.5 | dBm | ||
LOS Hysteresis | PD - PA | 0.5 | 6 | dB |
Notes:
1. Even if TDP is<0.9dB, the OMA min must exceed this value.
Electrical Characteristics
Parameter | Symbol | Min. | Typ. | Max. | Unit | Note |
Supply Voltage | VCC1, | 3.15 | 3.45 | V | ||
VCCTX, | 3.15 | 3.45 | V | |||
VCCRX | 3.15 | 3.45 | V | |||
Transmitter | ||||||
Input different impedance | Rin | 90 | 100 | 110 | Ω | 2 |
Single ended data input swing | Vin,pp | 120 | 820 | mV | ||
Transmitter Disable Voltage | VDIS | 2 | VCC | V | 3 | |
Transmitter Enable Voltage | VEN | 0 | 0.8 | V | ||
Data Dependent Input Jitter | DDJ | 0.3 | UI | |||
Receiver | ||||||
Output different impedance | Rout | 90 | 100 | 110 | Ω | 2 |
Single ended data output swing | Vout,pp | 340 | 850 | mV | 4 | |
LOS Asserted | VLOSA | 2 | VCCHOST | V | 5 | |
LOS De-asserted | VLOSD | 0 | 0.8 | V | 5 | |
Power Supply Rejection | PSR | 50 | mVpp |
Notes:
1. Maximum total power value is specified across the full temperature and voltage range.
2. Connected directly to TX data input pins. AC coupled thereafter.
3. Or open circuit.
4. Into 100Ω differential termination.
5. Loss of Signal is LVTTL. Logic “0”indicates normal operation; logic “1” indicates no signal detected.
64G SFP56 850nm 100m
40G QSFP+ ER4 Industrial 40 km
40G QSFP+ ER4 40 km
40G QSFP+ LR4 Industrial 10 km
40G QSFP+ PSM4 2 km
40G QSFP+ PLR4 1310 nm 10 km
40G QSFP+ CSR4 300m
40GBASE-UNIV QSFP+ MMF and SMF
40G QSFP+ CWDM 2 km
40G QSFP CWDM 20 km
40G QSFP+ SR4 300 m
40G QSFP+ SR4 150 m
40G QSFP+ BIDI 150m
32G SFP28 SR 850 nm 100 m
25G SFP28 CWDM 10 km(E)
25G SFP28 ZR 1310nm 80km
25G SFP28 1310 nm 40km
25G SFP28 1310 nm 10 km
25G SFP28 850 nm 300m
25G SFP28 850 nm 100m
10/25G SFP28 1310nm 40km
10/25G SFP28 1310nm 10km
10/25G SFP28 850 nm 300m
10/25G SFP28 850 nm 100m