ABA1000 Battery Management Station is a battery management system used to maintain, reactivate and test battery cells up to 12V. This system includes a battery charger, a battery discharger, a battery activator and system monitor.
• Charger, discharger, and activator functionality which can be used either separately or comprehensively
• Compatible with 2 V, 6 V, and 12 V battery cells
• Charges/discharges single and multi-cell batteries
• Constant current discharging with current, time and voltage setting
• Charging/discharging automatic stop with test time, capacity setting and over current protection
• Alarm when high temperature, opposing connection, battery wire disconnect, under or over voltage, over current conditions
• Data management software
• Easy-to-read LCD display
• Built-in safeguards to protect batteries during testing
• Highly accurate test results
• Compact design to save space
• Three stage charging: Constant current, Fixed Voltage, Reduced current – floating
ABA1000 Battery Management System
Item  | 12 V ( 2V, 6V optional )  | |
Charge Current per Cell Voltage  | Up to 15 A +/-0.01A  | |
Discharge Current per Cell Voltage  | Up to 50 A +/-0.01A  | |
Charge and Discharge Voltage  | 9.0V to 16 V  | |
Temperature Censor  | -10℃~55℃ +/- 0.001℃  | |
Impulse Cycle  | 15s  | |
Display  | 800 × 480 pixel color LCD with touch screen  | |
Power Requirements2  | 220 V±10% AC / 50 Hz  | |
Operation Temperature  | 0 to 50 °C  | |
Operation Humidity  | 5 % to 90 % RH (non-condensing)  | |
Communication Port  | RS232 or USB  | |
Dimensions (L × W × H)  | 42.5 mm × 20 mm × 30 mm  | |
Weight  | 15 kg  | |
1 Varies depending on battery capacity
2 Desired input voltage to be specified by customer